Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 221
Filtrar
1.
Jt Dis Relat Surg ; 32(1): 10-16, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33463412

RESUMO

OBJECTIVES: In this study, we present our 10-year postoperative follow-up results of Sanat Swing® and NexGen® total knee implants. PATIENTS AND METHODS: A total of 189 patients (93 males, 96 females; mean age: 68 years; range, 48 to 86 years) who underwent total knee replacement between January 2008 and September 2010 were retrospectively analyzed. A total of 105 patients (Group A) were implanted a cemented Sanat Swing knee prosthesis and 84 patients (Group B) were implanted a cemented NexGen knee prosthesis. Operation time, range of motion (ROM), pain level, Knee Society Score (KSS), distance of painless walking, and the ability to climb stairs were evaluated between the groups. RESULTS: The mean follow-up was 10.8 (range, 9.8 to 12.3) years. No significant difference was observed in the survival of the prostheses, ROM, pain level, KSS, walking distance, and in the ability to climb stairs between the two groups at 10 years. With an experienced team, the operation time was about 4 to 5 min shorter in the Sanat Swing implantation group. In selected cases, Sanat Swing was superior to the NexGen system; however, there was no statistically significant difference. Complication rates were also low and comparable between both groups. CONCLUSION: Based on the 10 years of follow-up evaluation, Sanat Swing total knee replacement system seems to yield comparable clinical results with the NexGen. Experiences with the operative technique and comparative evaluation, the Sanat Swing system is a safe and reliable alternative for total knee replacement, providing a user-friendly operative technique and shorter operation time.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Efeitos Adversos de Longa Duração , Complicações Pós-Operatórias , Idoso , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/instrumentação , Artroplastia do Joelho/métodos , Pesquisa Comparativa da Efetividade , Feminino , Seguimentos , Estado Funcional , Humanos , Hungria/epidemiologia , Articulação do Joelho/cirurgia , Prótese do Joelho/efeitos adversos , Prótese do Joelho/normas , Efeitos Adversos de Longa Duração/diagnóstico , Efeitos Adversos de Longa Duração/epidemiologia , Efeitos Adversos de Longa Duração/etiologia , Masculino , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos
2.
Acta Orthop Traumatol Turc ; 54(5): 502-506, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33155559

RESUMO

OBJECTIVE: This study aimed to determine the effects of the microprocessor-controlled prosthetic knee (MPK) joint on self-mobility, body perceptions, depression, and quality of life in patients with unilateral transfemoral amputations (TFAs). METHODS: Thirty consecutive patients (28 males, mean age=38.5 years, age range=22-57) who had previously used non-MPKs and who were approved to use swing and stance phase-control MPKs were included in this 12-week clinical study. Before the MPK use and after the three-month follow-up, prosthetic use and locomotor capabilities were evaluated using the Houghton Scale and the Locomotor Capabilities Index (LCI-5), respectively. Body perception was assessed using the Amputee Body Image Scale (ABIS). The depressive symptoms and quality of life were evaluated using the Beck Depression Inventory (BDI) score and the 36-Item Short- Form Health Survey (SF-36), respectively. RESULTS: After MPK use, statistically significant ameliorations were observed in all outcome measures. The basic and advanced LCI-5 increased from 26.7±2.2 and 24.8±5.2 to 27.6±1.2 (p=0.007) and 27±2.1 (p=0.004), respectively. Houghton scores improved from 9±1 to 10.3±0.8 (p=0.000). The ABIS and BDI scores decreased from 43.2±10.9 and 5.7±6.6 to 37.1±8.9 (p=0.000) and 3.8±4.5 (p=0.015), respectively. Also, the SF-36 physical function and vitality subscales increased from 71.2±24.0 and 75.5±14.6 to 85.6±16.6 (p=0.001) and 81.7±14.1 (p=0.015), respectively. CONCLUSION: MPK use provides significant improvements in the locomotor capabilities, quality of life, and activities of daily living to patients with TFAs as well as improves their body image perceptions and depressive symptoms. LEVEL OF EVIDENCE: Level III, Self controlled study.


Assuntos
Amputação Cirúrgica , Fêmur/cirurgia , Prótese do Joelho , Microcomputadores , Qualidade de Vida , Atividades Cotidianas , Adulto , Amputação Cirúrgica/métodos , Amputação Cirúrgica/psicologia , Amputação Cirúrgica/reabilitação , Feminino , Humanos , Prótese do Joelho/classificação , Prótese do Joelho/psicologia , Prótese do Joelho/normas , Masculino , Limitação da Mobilidade , Desenho de Prótese , Melhoria de Qualidade , Autorrelato
3.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 34(6): 696-701, 2020 Jun 15.
Artigo em Chinês | MEDLINE | ID: mdl-32538558

RESUMO

OBJECTIVE: To evaluate the effect of the surgeon's handedness on the distribution of prosthesis during primary total knee arthroplasty (TKA). METHODS: A retrospective analysis was performed on 86 patients (100 knees) with primary TKA completed by the same right-handed surgeon between December 2016 and December 2018, including 72 cases of single knee and 14 of bilateral knees. The patients were divided into dominant group (right side) and non-dominant group (left side) according to the operating position of the surgeon and each group had 50 knees. There was no significant difference in gender, age, body mass index, disease duration, clinical diagnosis, preoperative Hospital for Special Surgery (HSS) score, and other general data between the two groups ( P>0.05). The operation time and complications were recorded in both groups. The function of knee was evaluated by HSS score. Hip-knee-ankle angle (HKA), mechanical lateral distal femoral angle (mLDFA), and mechanical medial proximal tibial angle (mMPTA) were measured by using X-ray film of full-length lower extremity before TKA and at 2 weeks after TKA that were used to evaluate the coronal position of the prosthesis. Posterior distal femoral angle (PDFA) and posterior proximal tibial angle (PPTA) were measured by using lateral X-ray films at 3 months after operation that were used to evaluate the sagittal position of the prosthesis. RESULTS: There was no significant difference in operation time between the two groups ( t=-1.128, P=0.262). One case of posterior tibial artery thrombosis occurred in the dominant group, and 1 case of poor healing of the incision occurred in each of the dominant group and the non-dominant group. Patients in both groups were followed up 12-34 months with an average of 22.0 months. The HSS scores at last follow-up were 87.2±4.3 in the dominant group and 86.8±5.0 in the non-dominant group. There was no significant difference between the two groups ( t=0.471, P=0.639). No complications such as periprosthetic infection, prosthetic loosening, or periprosthetic fracture occurred during follow-up. There was no significant difference in the HKA, mLDFA, and mMPTA between the two groups before and after operation ( P>0.05). The differences in the incidence of sagittal femoral prosthesis malposition and PDFA between the two groups were significant ( P<0.05); however, there was no significant difference in the PPTA, the rate of femoral prosthesis distributed in the neutral position, the incidence of over-flexed femoral prosthesis, and the incidence of anterior femoral notch ( P>0.05). CONCLUSION: The surgeon's handedness is one of the factors affecting the placement of the sagittal femoral prosthesis in primary TKA. The incidence of sagittal femoral prosthesis malposition could increase when the surgeon performs on the non-dominant side.


Assuntos
Artroplastia do Joelho , Lateralidade Funcional , Cirurgiões , Artroplastia do Joelho/normas , Artroplastia do Joelho/estatística & dados numéricos , Humanos , Articulação do Joelho , Prótese do Joelho/normas , Osteoartrite do Joelho , Estudos Retrospectivos , Cirurgiões/estatística & dados numéricos
4.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 34(6): 751-755, 2020 Jun 15.
Artigo em Chinês | MEDLINE | ID: mdl-32538567

RESUMO

OBJECTIVE: To investigate the short-term effectiveness of three-dimensional (3D) printing personalized prosthesis in the treatment of giant cell tumor of bone around knee joint. METHODS: A clinical data of 9 patients with giant cell tumor of bone around knee joints and met the inclusive criteria between May 2014 and August 2017 was retrospectively analysed. There were 4 males and 5 females, with an average age of 35.8 years (range, 24-50 years). The lesion located at the distal femur in 4 cases and at the proximal tibia in 5 cases. The disease duration was 5-25 months (mean, 12.9 months). According to Campanacci grading, there were 2 patients of grade Ⅰ and 7 of grade Ⅱ. The 3D printing personalized prosthesis was designed based on the CT scanning and 3D reconstruction prepared before operation. All patients were treated with the tumor resection and 3D printing personalized prosthesis reconstruction. The radiological examination was taken to observe the tumor recurrence and the Musculoskeletal Tumor Society 1993 (MSTS93) score was used to evaluate the knee function. RESULTS: All operations were successful and all incisions healed by first intention without early complications. All patients were followed up 24-40 months (mean, 31.2 months). At last follow-up, no complication such as pain, pathological fracture, prosthesis loosening, or tumor recurrence occurred. The MSTS93 score was 20-29 (mean, 24.7). The knee function was rated as excellent in 6 cases and good in 3 cases, with the excellent and good rate of 100%. CONCLUSION: For giant cell tumor of bone around knee joint, 3D printing personalized prosthesis has the advantages of bio-fusion with host bone, mechanical stability, good joint function, and ideal short-term effectiveness. But the middle- and long-term effectiveness still need to be further observed.


Assuntos
Neoplasias Ósseas , Tumor de Células Gigantes do Osso , Prótese do Joelho , Impressão Tridimensional , Adulto , Neoplasias Ósseas/reabilitação , Neoplasias Ósseas/cirurgia , Feminino , Tumor de Células Gigantes do Osso/reabilitação , Tumor de Células Gigantes do Osso/cirurgia , Humanos , Articulação do Joelho/cirurgia , Prótese do Joelho/normas , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
5.
BMC Musculoskelet Disord ; 21(1): 107, 2020 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-32066423

RESUMO

BACKGROUND: The Flexible Nichidai Knee Posterior Stabilized (FNK-PS) system was designed to provide relatively high varus-valgus stabilities without the stem extensions to patients with severe knee joint disorders. This is a combination of a large tibial post and high femoral cam adapted to a PS system. The aim of our study was to analyze the in vivo two-dimensional/three-dimensional registration kinematics of the FNK PS-total knee arthroplasty (TKA) system during deep knee bending. METHODS: Nineteen knees from 15 total knee arthroplasty (TKA) patients who were able to squat with enough knee flexion were selected. During deep knee bending under weight bearing (WB) and non-weight bearing (NWB) conditions, we quantified range of motion, axial rotation, femoral anteroposterior translation, and post-cam engagement angle. RESULTS: The maximum-flexion was significantly different between the two conditions. The mean axial femoral external rotation was 4.8° and 6.2° under WB and NWB conditions, respectively, at 120° flexion. Anteroposterior translation based on bicondylar posterior roll-back patterns was noted with increasing knee flexion. Both the medial and lateral femoral aspects were significantly more posterior during early to mid-flexion. Initial post-cam engagement occurred significantly earlier during flexion under NWB than under WB conditions. Under WB, the timing of the post-cam engagement correlated with the maximum flexion . CONCLUSIONS: The kinematics of the semi-constrained PS system reproducibly exhibited a mild external rotation with smooth posterior roll-back. This was assisted by the engagement of the large tibial post and high femoral cam during the early phase of flexion.


Assuntos
Artroplastia do Joelho/métodos , Fenômenos Biomecânicos/fisiologia , Articulação do Joelho/fisiologia , Articulação do Joelho/cirurgia , Prótese do Joelho/normas , Amplitude de Movimento Articular/fisiologia , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/instrumentação , Feminino , Seguimentos , Humanos , Articulação do Joelho/diagnóstico por imagem , Pessoa de Meia-Idade
6.
Bone Joint J ; 101-B(11): 1356-1361, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31674235

RESUMO

AIMS: Knee osteonecrosis in advanced stages may lead to joint degeneration. Total knee arthroplasty (TKA) for osteonecrosis has traditionally been associated with suboptimal results. We analyzed outcomes of contemporary TKAs for osteonecrosis, with particular emphasis on: survivorship free from aseptic loosening, any revision, and any reoperation plus the clinical outcomes, complications, and radiological results. PATIENTS AND METHODS: In total, 156 patients undergoing 167 primary TKAs performed for osteonecrosis between 2004 and 2014 at a single institution were reviewed. The mean age at index TKA was 61 years (14 to 93) and the mean body mass index (BMI) was 30 kg/m2 (18 to 51) The mean follow-up was six years (2 to 12). A total of 110 TKAs (66%) were performed for primary osteonecrosis and 57 TKAs (34%) for secondary osteonecrosis. Overall, 15 TKAs (9%) had tibial stems, while 12 TKAs (7%) had femoral stems. Posterior-stabilized designs were used in 147 TKAs (88%) of TKAs. Bivariate Cox regression analysis was conducted to identify risk factors for revision and reoperation. RESULTS: Survivorship free from aseptic loosening, any revision, and any reoperation at ten years was 97% (95% confidence interval (CI) 93 to 100), 93% (95% CI 85 to 100), and 82% (95% CI 69 to 93), respectively. No factors, including age, sex, BMI, primary versus secondary osteonecrosis, stem utilization, and constraint, were identified as risk factors for reoperation. Four TKAs (2%) underwent revision, most commonly for tibial aseptic loosening (n = 2). Excluding revisions and reoperations, there was a total of 11 complications (7%), with the most common being a manipulation under anaesthesia (six TKAs, 4%). Mean Knee Society Scores (Knee component) significantly improved from 57 (32 to 87) preoperatively to 91 (49 to 100) postoperatively (p < 0.001). No unrevised TKAs had complete radiolucent lines or radiological evidence of loosening. CONCLUSION: Contemporary cemented TKAs with selective stem utilization for osteonecrosis resulted in durable survivorship, a low complication rate, and reliable improvement in clinical outcomes. Cite this article: Bone Joint J 2019;101-B:1356-1361.


Assuntos
Artroplastia do Joelho/normas , Prótese do Joelho/normas , Osteonecrose/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Falha de Prótese , Reoperação/estatística & dados numéricos , Resultado do Tratamento , Adulto Jovem
7.
Bone Joint J ; 101-B(11): 1348-1355, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31674253

RESUMO

AIMS: A retrospective study was conducted to measure short-term in vivo linear and volumetric wear of polyethylene (PE) inserts in 101 total knee arthroplasty (TKA) patients using model-based radiostereometric analysis (MBRSA). PATIENTS AND METHODS: Nonweightbearing supine RSA exams were performed postoperatively and at six, 12, and 24 months. Weightbearing standing RSA exams were performed on select patients at 12 and 24 months. Wear was measured both linearly (joint space) and volumetrically (digital model overlap) at each available follow-up. Precision of both methods was assessed by comparing double RSA exams. Patient age, sex, body mass index, and Oxford Knee Scores were analyzed for any association with PE wear. RESULTS: Linear wear occurred at 0.015 mm/year (supine) and 0.220 mm/year (standing). Volumetric wear occurred at 10.3 mm3/year (supine) and 39.3 mm3/year (standing). Wear occurred primarily on the medial side of the joint. Weightbearing imaging greatly improved the reliability of measurement. Clinical precision of volumetric wear was 34 mm3. No significant associations were found between patient demographics or function scores and measured wear. CONCLUSION: In vivo volumetric wear of TKAs can be assessed at short-term follow-up using MBRSA. Cite this article: Bone Joint J 2019;101-B:1348-1355.


Assuntos
Artroplastia do Joelho/normas , Prótese do Joelho/normas , Falha de Prótese , Artroplastia do Joelho/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Análise Radioestereométrica , Estudos Retrospectivos , Posição Ortostática , Decúbito Dorsal
8.
J Orthop Surg Res ; 14(1): 139, 2019 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-31097037

RESUMO

BACKGROUND: Single-radius (SR) prostheses and multi-radius (MR) prostheses have different theoretical advantages; however, there has been a paucity of evaluations comparing the two. This study was designed to compare the 10-year clinical, radiological, and survival outcomes of SR and MR posterior-stabilized prostheses in total knee arthroplasty (TKA). METHODS: In this retrospective cohort study, 220 consecutive patients undergoing TKA between October 2006 and October 2007 were divided into the SR group (106 patients, Stryker Scorpio NRG) and the MR group (114 patients, DePuy Sigma PFC), with a minimum follow-up of 10 years. Clinical, functional, and radiological outcomes, as well as satisfaction rates and survival results, were evaluated. RESULTS: Hospital for Special Surgery and Short Form-12 health survey scores were all significantly improved in both groups at the final follow-up (P < 0.05), but the groups did not differ. The SR group had significantly less anterior knee pain (AKP) and painless crepitation (P < 0.05). Radiological results in terms of radiolucent lines and component position angle showed no differences between groups. The Kaplan-Meier survival curve estimates at 10 years were not significantly different between the groups (P = 0.4172). CONCLUSION: Both SR and MR posterior-stabilized prostheses can lead to satisfactory outcomes. The SR prosthesis design gave less anterior knee pain than did the MR prostheses. Two prostheses showed no differences in terms of clinical scales, radiological results, satisfaction rates, and survival results at a long-term follow-up. More accurate measurements are required.


Assuntos
Artroplastia do Joelho/tendências , Prótese do Joelho/tendências , Desenho de Prótese/tendências , Rádio (Anatomia)/cirurgia , Idoso , Artroplastia do Joelho/instrumentação , Estudos de Coortes , Feminino , Seguimentos , Humanos , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/cirurgia , Prótese do Joelho/normas , Masculino , Pessoa de Meia-Idade , Desenho de Prótese/normas , Rádio (Anatomia)/diagnóstico por imagem , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
9.
BMJ Open ; 9(4): e026736, 2019 04 29.
Artigo em Inglês | MEDLINE | ID: mdl-31036709

RESUMO

OBJECTIVES: To investigate the relative performance of knee replacement constructs compared with the best performing construct and illustrate the substantial variability in performance. DESIGN: A non-inferiority study. SETTING: England and Wales. PARTICIPANTS: All primary total and unicondylar knee replacements performed and registered in the National Joint Registry between 1 April 2003 and 31 December 2016. MAIN OUTCOME MEASURES: Kaplan-Meier failure function for knee replacement constructs. Failure difference between best performing construct (the benchmark) and other constructs. METHODS: Using a non-inferiority analysis, the performance of knee replacement constructs by brand were compared with the best performing construct. Construct failure was estimated using the 1-Kaplan Meier method, that is, an estimate of net failure. The difference in failure between the contemporary benchmark construct and all other constructs were tested. RESULTS: Of the 449 different knee replacement constructs used, only 27 had ≥500 procedures at risk at 10 years postprimary, 18 of which were classified as inferior to the benchmark by at least 20% relative risk of failure. Two of these 18 were unicondylar constructs that were inferior by at least 100% relative risk. In men, aged 55-75 years, 12 of 27 (44%) constructs were inferior by at least 20% to the benchmark at 7 years postprimary. In women, aged 55-75 years, 8 of 32 (25%) constructs were inferior at 7 years postprimary. Very few constructs were classified as non-inferior to the contemporary benchmark. CONCLUSIONS: There are few knee replacement constructs that can be shown to be non-inferior to a contemporary benchmark. Unicondylar knee constructs have, almost universally, at least 100% worse revision outcomes compared with the best performing total knee replacement. These results will help to inform patients, clinicians and commissioners when considering knee replacement surgery.


Assuntos
Artroplastia do Joelho/estatística & dados numéricos , Prótese do Joelho/normas , Desenho de Prótese/normas , Falha de Prótese , Idoso , Artroplastia do Joelho/normas , Benchmarking/métodos , Inglaterra , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Irlanda do Norte , Sistema de Registros , Distribuição por Sexo , Fatores de Tempo , País de Gales
10.
BMC Musculoskelet Disord ; 20(1): 97, 2019 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-30832636

RESUMO

BACKGROUND: More personalized implant designs for total knee arthroplasty might optimize the clinical outcome after surgery. One of these personalized implant designs is the Persona knee implant system (Zimmer Biomet, Warsaw, Indiana, USA). The primary objective of this study was to determine patient reported outcomes and implant survivorship of the Persona Knee system used in primary total knee arthroplasty, up to two years after surgery. METHODS: From November 2013 to July 2016 consecutive patients undergoing primary total knee arthroplasty were enrolled in a prospective observational cohort study at three centers. Preoperatively, at 6 weeks, 6 months, 1 and 2 years after surgery, patients completed the Knee Injury and Osteoarthritis Outcome Score (KOOS), the Oxford Knee Score (OKS), the Knee Society Score (KSS, 2011, modified version) and the EQ-5D. Adverse Events were captured, assessed for relationship to device, and recorded in the study database. Furthermore, physical functioning was assessed by the orthopedic surgeon. Repeated measures analyses were performed on PROM scores. Kaplan Meier was used to calculate survivorship of the Persona Knee Implant System. RESULTS: A total of 146 total knee arthroplasties were performed. 61% (89/146) of the patients were female and mean age was 64.7 (± 6.9) years. Two years after surgery, one patient had a revision of the polyethylene insert because of a periprosthetic joint infection. Therefore, the Kaplan-Meier survival estimate at 2 years was 0.99 (0.95-1.00 95% CI). OKS increased from 22.1 (95% CI 20.9-23.3) to 41.8 (95% CI 40.6-43.1) two years after surgery. Furthermore, all other PROMs also increased from before surgery to 2 year postoperatively. CONCLUSION: The Persona Knee implant is safe and effective and the clinical results up to two years after surgery are promising. PROMs results are very good; pain, function and quality of life all improved greatly after TKA. Further studies are needed to determine the long term clinical performance of the Persona prosthesis. TRIAL REGISTRATION: Clinicaltrials.gov ( NCT02337244 ). Registered June 1st, 2015. Retrospectively registered.


Assuntos
Artroplastia do Joelho/instrumentação , Artroplastia do Joelho/tendências , Prótese do Joelho/tendências , Medidas de Resultados Relatados pelo Paciente , Cuidados Pós-Operatórios/tendências , Idoso , Artroplastia do Joelho/normas , Estudos de Coortes , Feminino , Seguimentos , Humanos , Prótese do Joelho/normas , Masculino , Pessoa de Meia-Idade , Cuidados Pós-Operatórios/normas , Estudos Prospectivos , Fatores de Tempo
11.
J Biomech ; 86: 117-124, 2019 03 27.
Artigo em Inglês | MEDLINE | ID: mdl-30777340

RESUMO

Misalignment and soft-tissue imbalance in total knee arthroplasty (TKA) can cause discomfort, pain, inadequate motion and instability that may require revision surgery. Balancing can be defined as equal collateral ligament tensions or equal medial and lateral compartmental forces during the flexion range. Our goal was to study the effects on balancing of linear femoral component misplacements (proximal, distal, anterior, posterior); and different component rotations in mechanical alignment compared to kinematic alignment throughout the flexion path. A test rig was constructed such that the position of a standard femoral component could be adjusted to simulate the linear and rotational positions. With the knee in neutral reference values of the collateral tensions were adjusted to give anatomic contact force patterns, measured with an instrumented tibial trial. The deviations in the forces for each femoral component position were then determined. Compartmental forces were significantly influenced by 2 mm linear errors in the femoral component placement. However, the errors were least for a distal error, equivalent to undercutting the distal femur. The largest errors mainly increase the lateral condyle force, occurred for proximal and posterior component errors. There were only small contact force differences between kinematic and mechanical alignment. Based on these results, surgeons should avoid overcutting the distal femur and undercutting the posterior femur. However, the 2-3 degrees varus slope of the joint line as in kinematic alignment did not have much effect on balancing, so mechanical or kinematic alignment were equivalent.


Assuntos
Artroplastia do Joelho/métodos , Artroplastia do Joelho/normas , Fêmur/cirurgia , Prótese do Joelho/normas , Joelho/cirurgia , Modelos Anatômicos , Fenômenos Biomecânicos , Humanos , Erros Médicos , Equilíbrio Postural , Amplitude de Movimento Articular
12.
BMJ Case Rep ; 12(1)2019 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-30642854

RESUMO

A 58-year-old morbidly obese male (body mass index: 38 kg/m2) with severe haemophilia A underwent total knee replacement surgery. Perioperatively, factor VIII (FVIII) levels were measured daily and maximum a posteriori (MAP) Bayesian estimation was used to calculate the individual pharmacokinetic (PK) parameters and doses required to obtain prescribed FVIII target levels. In the MAP Bayesian procedure, a population PK model was used in which PK parameters were normalised using body weight. In this specific case, ideal body weight was used to scale the PK parameters instead of actual body weight. Except for the preoperative FVIII level, adequate FVIII levels were achieved during the 10-day perioperative period. During follow-up visits, the knee prosthesis was reported to function adequately.


Assuntos
Artroplastia do Joelho/instrumentação , Fator VIII/farmacocinética , Hemofilia A/tratamento farmacológico , Assistência ao Convalescente , Artroplastia do Joelho/métodos , Coagulantes/farmacocinética , Fator VIII/uso terapêutico , Hemofilia A/prevenção & controle , Humanos , Prótese do Joelho/normas , Masculino , Pessoa de Meia-Idade , Obesidade Mórbida/epidemiologia , Procedimentos Ortopédicos , Período Perioperatório , Resultado do Tratamento
14.
PLoS One ; 13(10): e0206496, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30372460

RESUMO

ISO 14243 is the governing standard for wear testing of knee prostheses, but there is controversy over the correct direction of anterior-posterior (AP) displacement and loading and the correct direction of tibial rotation (TR) angles and torque. This study aimed to analyze how altering the direction of AP and TR affected wear on the tibial insert. Modifications to the conditions specified in ISO 14243-1 and ISO 14243-3 were also proposed. As such, five loading conditions were applied to FEA models of a knee prosthesis: (1) Modified ISO 14243-3 with positive AP displacement and TR angle, (2) ISO 14243-3:2004 with negative AP displacement and positive TR angle, (3) ISO 14243-3:2014 with positive AP displacement and negative TR angle, (4) Modified ISO 14243-1 with positive AP load and TR torque, and (5) ISO 14243-1:2009 with negative AP load and positive TR torque. This study found that changing the input directions for AP and TR according to ISO 14243-1 and 14243-3 had an influence on the wear rate and wear contours on the tibial insert model. However, the extent of wear varies depending on the design features of the tibial insert and shape of the input curves. For displacement control according to ISO 14243-3, changing the direction of AP displacement had a marked influence on the wear rate (272.77%), but changing the direction of TR angle had a much lower impact (2.17%). For load control according to ISO 14243-1, reversing the AP load (ISO 14243-1:2009) only increased the wear rate by 6.73% in comparison to the modified ISO 14243-1 conditions. The clinical relevance of this study is that the results demonstrate that tibial wear is affected by the direction of application of AP and TR. Incorrect application of the loading conditions during the design stage may lead to an ineffective preclinical evaluation and could subsequently influence implant longevity in clinical use.


Assuntos
Prótese do Joelho/normas , Artroplastia do Joelho/instrumentação , Artroplastia do Joelho/normas , Fenômenos Biomecânicos , Marcha , Humanos , Prótese do Joelho/efeitos adversos , Falha de Prótese , Amplitude de Movimento Articular , Torque , Suporte de Carga
15.
Zhejiang Da Xue Xue Bao Yi Xue Ban ; 47(3): 313-319, 2018 05 25.
Artigo em Chinês | MEDLINE | ID: mdl-30226335

RESUMO

Total knee arthroplasty is an effective method for the treatment of end-stage knee osteoarthrosis, which can effectively relieve joint pain and reconstruct the integrity of the joint. Whether the posterior cruciate ligament should be preserved during surgery or not, which is still in dispute. In recent years, posterior cruciate-retaining and substituting total knee prostheses are both applied in clinical practice. Both domestic and international studies have shown that there are no significant difference in patient satisfaction, knee flexion, survival rate of the prosthesis and the main clinical manifestations between two prostheses. However, posterior cruciate-retaining total knee prosthesis is more consistent with the normal physiology and biomechanics of the human body. The gait is more balanced and proprioceptive when walking up and down the stairs, but when the joints are buckling, the femur is abnormal to move back to the tibia, resulting in abnormal motion. While posterior cruciate-substituting total knee prosthesis can correct severe deformity of the knee, and keep better balance between flexion and extension of the knee joint, but there is a potential complication of patellar clunk syndrome. Therefore, under the same conditions, the younger patients may prefer to chose posterior cruciate-retaining total knee prosthesis, while elder patients may prefer to chose posterior cruciate-substituting total knee prosthesis. This paper reviews the function of posterior cruciate ligament, as well as the advantages and disadvantages of two prostheses, so as to provide some references for clinic.


Assuntos
Artroplastia do Joelho , Ligamento Cruzado Posterior , Artroplastia do Joelho/métodos , Artroplastia do Joelho/normas , Humanos , Articulação do Joelho/cirurgia , Prótese do Joelho/normas , Ligamento Cruzado Posterior/fisiologia , Ligamento Cruzado Posterior/cirurgia
16.
BMC Musculoskelet Disord ; 19(1): 234, 2018 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-30021581

RESUMO

BACKGROUND: Component design is one of the contributory factors affecting the postoperative flexion angle. The purpose of this study was to compare short-term outcomes of flat surface and medial pivot designs in posterior cruciate-retaining (CR) total knee arthroplasty (TKA). METHODS: A retrospective, case-control, and observational cohort study consisted of matched-pairs of the flat surface design (Hi-Tech Knee II) and the medial pivot design (FINE Knee) in CR-TKA with a two-year follow-up period. RESULTS: Hi-Tech Knee II and FINE knee groups each included 7 males and 38 females. Surgical time was significantly shorter in the FINE Knee group than in the Hi-Tech Knee II group (104.8 min versus 154.9 min, p = 0.001). Estimated total blood loss was significantly lower in the FINE Knee group than in the Hi-Tech Knee II group (654 ml versus 1158 ml, p = 0.001). The postoperative flexion angle was significantly better in the FINE Knee group than in the Hi-Tech Knee II group (119.3 degrees versus 112.5 degrees), and was positively correlated with the preoperative flexion angle. Postoperative Knee Society scores were significantly better in the FINE Knee group than in the Hi-Tech Knee II group (93.0 points versus 85.0 points, p = 0.001), especially for postoperative pain relief (46.0 points versus 39.0 points out of 50, p = 0.001). Complications were not observed in either group over a two-year follow-up period. CONCLUSION: The short-term outcome of the medial pivot design used in CR-TKA was more favorable than the flat surface design, especially for surgical time, estimated total blood loss, postoperative flexion angle, and knee pain.


Assuntos
Artroplastia do Joelho/instrumentação , Artroplastia do Joelho/normas , Prótese do Joelho/normas , Ligamento Cruzado Posterior/cirurgia , Desenho de Prótese/normas , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ligamento Cruzado Posterior/diagnóstico por imagem , Desenho de Prótese/métodos , Estudos Retrospectivos , Fatores de Tempo
17.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 62(3): 197-203, mayo-jun. 2018. ilus, tab, graf
Artigo em Espanhol | IBECS | ID: ibc-177323

RESUMO

Objetivo: Comparar dos pares de fricción (metal/polietileno de ultra alto peso molecular [UHMWPE], metal/polietileno de alto entrecruzamiento) mediante análisis cuantitativo y cualitativo de partículas de polietileno en líquido sinovial a los 3 años postintervención en pacientes portadores de prótesis total de rodilla (PTR). Material y métodos: Se llevó a cabo un estudio de cohortes prospectivo, aleatorizado, con evaluación ciega incluyendo 25 pacientes a quienes se intervino de PTR de manera bilateral, con 6 meses de diferencia. A los 3 años postintervención, se realizaron artrocentesis de rodilla a 12 pacientes y se analizaron las partículas de polietileno. Resultados: No se hallaron diferencias significativas en el número de partículas generadas por los diferentes insertos de polietileno a los 3 años tras la implantación de una artroplastia total de rodilla (3.000×: x¯ entrecruzado=849,7; x¯ UHMWPE=796,9; p=0,63; 20.000×: x¯ entrecruzado=66,3; x¯ UHMWPE=73,1; p=0,76). Tampoco existen diferencias significativas entre los 2 tipos de inserto, entre la posibilidad de encontrar partículas de forma elongada (χ2=0,19; p=0,66) ni redonda (χ2=1,44; p=0,23). Sin embargo, la probabilidad de encontrar partículas de forma fibrilar es 3,08 veces mayor en el UHMWPE. Conclusiones: El polietileno altamente entrecruzado no reduce significativamente la generación de partículas de polietileno en aquellos pacientes intervenidos mediante una artroplastia total de rodilla, con muestras a 3 años postintervención


Aim: To compare two different types of inserts: Ultra-high molecular weight polyethylene (UHMWPE) and cross-linked polyethylene with a quantitative and qualitative study of polyethylene wear particles in synovial fluid 3 years after total knee arthroplasty. Material and methods: A prospective, randomized, controlled cohort study with blinded evaluation was carried out on 25 patients undergoing staged bilateral total knee replacement, 6 months apart. Knee arthrocentesis was performed on 12 patients 3 years after surgery, and the polyethylene particles were analyzed. Results: No significant differences were found in the number of particles generated by the two different types of inserts at 3 years from total knee arthroplasty (3,000×: x¯ cross-linked=849.7; x¯ UHMWPE=796.9; P=.63; 20,000×: x¯ cross-linked=66.3; x¯ UHMWPE=73.1; P=.76). Likewise, no differences in the probability of finding elongated (χ2=0.19; P=.66) or rounded (χ2=1.44; P=.23) particles in both types of inserts were observed. However, the probability of finding fibrillar particles is 3.08 times greater in UHMWPE. Conclusions: Cross-linked polyethylene does not significantly reduce the generation of polyethylene particles in patients with total knee arthroplasty, 3 years after the surgical procedure


Assuntos
Humanos , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/métodos , Osteoartrite do Joelho/cirurgia , Prótese do Joelho/normas , Estudos Prospectivos , Materiais Biocompatíveis/análise , Polietileno/análise , Artrocentese/métodos , Falha de Prótese
18.
Arch Orthop Trauma Surg ; 138(6): 851-863, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29671089

RESUMO

INTRODUCTION: Revision knee arthroplasty is increasing, and in that case, bone loss management is still a challenging problem. In the last years, the body of literature and interest surrounding porous metal cones has grown, but few systematic evaluations of the existing evidence have been performed. The aim of our systematic review is to collect and critically analyze the available evidence about metal cones in revision knee arthroplasty especially focusing our attention on indications, results, complications, and infection rate of these promising orthopaedic devices. MATERIALS AND METHODS: We performed a systematic review of the available English literature, considering the outcomes and the complications of tantalum cones. The combinations of keyword were "porous metal cones", "knee revision", "bone loss", "knee arthroplasty", "periprosthetic joint infection", and "outcome". RESULTS: From the starting 312 papers available, 20 manuscripts were finally included. Only one included study has a control group. The main indication for metal cones is type IIb and III defects according AORI classification. Most of the papers show good clinical and radiological outcomes with low rate of complications. CONCLUSION: The examined studies provide encouraging clinical and radiological short-to-mid-term outcomes. Clinical studies have shown a low rate of aseptic loosening, intraoperative fractures, infection rate and a lower failure rate than the previous treatment methods. Higher quality papers are needed to draw definitive conclusions about porous metal cones.


Assuntos
Artroplastia do Joelho/instrumentação , Reabsorção Óssea/cirurgia , Artropatias/cirurgia , Articulação do Joelho/cirurgia , Prótese do Joelho/normas , Artroplastia do Joelho/métodos , Artroplastia do Joelho/normas , Materiais Biocompatíveis , Humanos , Metais , Reoperação , Tantálio
19.
Ann Pharm Fr ; 76(3): 228-234, 2018 May.
Artigo em Francês | MEDLINE | ID: mdl-29397920

RESUMO

OBJECTIVES: Single use patient-specific instruments (PSI) for total knee prosthesis are introduced as a new alternative to conventional ancillaries and computer assisted surgery by improving implants positioning. An exhaustive review was carried out to identify their specific characteristics, with their advantages and disadvantages. METHODS: Medical devices suppliers were consulted in 2015 for reviewing their PSI. Their technical, clinical and economic data were compared. The results had been submitted to an orthopaedics expert commission of our university hospital for clinical and financial opinion. RESULTS: Ten companies have provided the documentation for the analysis. PSI are manufactured by suppliers using a three dimensional printing method based on CT scans or MRI images. PSI are produced according to the surgeon's preferences after a preliminary data check, which can be performed by the suppliers' engineers, the surgeon and automatic calculation. Five suppliers can produce sterile PSI with optional delivery of 3D bone models. According to the experts, the studies failed to demonstrate the superiority of a PSI or hospital economic gain. The prices listed remain high and operating room time is not always significantly reduced. CONCLUSIONS: With the development of personalized medicine, the role of PSI grows in importance. They facilitate the surgeon's work by fully respecting the anatomy. These systems offer an interesting perspective in their technical and pedagogical aspects. But it seems premature to take them into routine use given the low number of high-level studies that were currently done.


Assuntos
Prótese do Joelho/normas , Medicina de Precisão/métodos , Artroplastia do Joelho/normas , Humanos , Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética , Impressão Tridimensional , Tomografia Computadorizada por Raios X
20.
J Arthroplasty ; 33(4): 1069-1075, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29195851

RESUMO

BACKGROUND: The effect of referencing system on posterior condylar offset (PCO) after total knee arthroplasty (TKA) is still controversial. Moreover, there is a lack of concern about the anterior flange-bone contact according to the referencing system. METHODS: One hundred four TKAs using the anterior referencing (AR) system and 107 TKAs using the posterior referencing (PR) system were analyzed with 2-year follow-up. The PCO, PCO ratio (PCOR), and contact at the anterior flange-bone interface were compared between the 2 groups. The flexion and extension gaps and the degree of medial release were measured, and clinical outcomes were evaluated. Finally, the correlation between changes in PCO and knee flexion angle was analyzed. RESULTS: The mean postoperative PCO and PCOR were significantly larger in the PR group than in the AR group. Incomplete contact between the anterior flange and anterior femur occurred more frequently in the AR group than in the PR group (48.1% vs 13.1%, P < .001). The medial and lateral flexion gaps were significantly larger in the AR group than in the PR group. The groups showed no differences in soft tissue release, degree of flexion, and clinical scores. In both groups, there was no correlation between postoperative change of PCO and improvement in flexion. CONCLUSION: The PR system produced larger PCO and PCOR, and smaller flexion gap compared to the AR system. Additionally, the PR group showed more favorable contact between the anterior flange and anterior femur. However, these differences were not related to the degree of soft tissue release and clinical outcomes.


Assuntos
Artroplastia do Joelho , Fêmur/cirurgia , Articulação do Joelho/cirurgia , Prótese do Joelho/normas , Amplitude de Movimento Articular , Idoso , Feminino , Humanos , Período Intraoperatório , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Estudos Prospectivos , Método Simples-Cego , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...